Pioneers in the industry, we offer current limiting reactor, 50 kva onan type reactor and oil immersed compensating reactor from India.
₹ 750000 / Piece Get Latest Price
| Voltage | 380 V |
| Usage/Application | Transmission & Distribution Networks |
| Power | 100 kW |
| Country of Origin | Made in India |
| Phase | Three |
| Frequency | 50 Hz |
Minimum order quantity: 1 Piece
Current Limiting Reactor is an inductive device inserted into an electrical circuit to limit the magnitude of short-circuit or fault currents. By adding inductive reactance, it reduces the instantaneous fault current, protecting equipment and improving system stability.
2. PurposeTo limit short-circuit currents and reduce mechanical and thermal stresses on electrical equipment.
To protect transformers, switchgear, cables, and generators from high fault currents.
To improve selectivity and coordination of protection devices.
To reduce voltage dips and transient disturbances during faults.
To enable the use of lower-rated circuit breakers by controlling fault currents.
| Component | Description |
|---|---|
| Core | Laminated silicon steel core for magnetic flux |
| Windings | Copper or aluminum wire insulated and wound on the core |
| Cooling | Dry type or oil immersed depending on rating |
| Enclosure | Metal tank (for oil cooled) or air ventilated enclosure (dry type) |
| Bushings | For external electrical connections |
₹ 190000 / Piece Get Latest Price
| Power | 50 kVA |
Minimum order quantity: 1 Piece
ONAN Type Reactor Rating Chart
We offer high-performance ONAN (Oil Natural Air Natural) Type Oil-Immersed Reactors used for power factor correction, voltage regulation, and harmonic mitigation in medium and high voltage electrical systems. These reactors are specifically designed for efficient heat dissipation and reliable operation under continuous electrical stress.
🔧 Key Specifications:
Type: Oil-Immersed, ONAN-Cooled Reactor
Power Rating: 100 kVAR to 50 MVAR
System Voltage: 6.6 kV / 11 kV / 22 kV / 33 kV / 66 kV / 132 kV
Cooling Type: ONAN (Oil Natural Air Natural)
Frequency: 50 Hz / 60 Hz
Winding Material: Copper / Aluminium
Installation: Outdoor / Indoor
Mounting: Plinth or Skid Base Mounted
Impedance Tolerance: ±10%
Insulation Class: Class A / B / F
Standards: IS 5553 / IS 2026 / IEC 60076-6 / IEEE
✅ Key Features:
ONAN cooling ensures natural and passive heat dissipation
High thermal and short-circuit withstand capacity
Durable tank design with weatherproof construct
₹ 100000 / Piece Get Latest Price
| Usage/Application | Industrial Facilities |
| Power | 750 kVA |
| Voltage | 380 V |
| Country of Origin | Made in India |
| Frequency | 50 Hz |
| Power Source | Electric |
Minimum order quantity: 1 Piece
Oil-Immersed Compensating Reactor Rating Chart
We offer a range of Oil-Immersed Compensating Reactors, specially designed for voltage regulation and reactive power compensation in medium- and high-voltage power systems. These reactors are essential in maintaining grid stability, managing load balancing, and minimizing voltage dips during switching or heavy inductive loads.
🔧 Key Specifications:
Type: Oil-Immersed Compensating / Shunt / Series Reactor
Power Rating (kVAR): 100 kVAR to 5000 kVAR
System Voltage: 6.6 kV / 11 kV / 22 kV / 33 kV
Frequency: 50 Hz / 60 Hz
Reactance Tuning Range: As per system design (5% to 15%)
Cooling Type: ONAN (Oil Natural Air Natural)
Insulation Class: Class A / B / F (as required)
Impedance Tolerance: ±10%
Winding Material: Copper / Aluminium
Mounting: Plinth / Skid Base
Standards: IS 5553, IS 2026, IEC 60289, IEEE
✅ Features:
Controls reactive power and supports lagging power factor correction
Reduces overvoltage during capacitor bank switchin
Mukesh Patil
Mudico Energy Private Limited
Shed No. 13, Shri Hari Darshan Industrial Park, Nika Tube Char Rasta, B/H Gidc Phase 4, NR., Trikampura Garnala, Ramol
Ahmedabad - 382445, Gujarat, India